Model 9200 CODS
Cannabis oil distillation system

Spinning Band Cannabis Distillation

Single-pass cannabinoid refining on a high-plate spinning band column, under automatic control with recorded run data.

Purity, first pass
90–95% TAC
Throughput
0.5–3.6 L/hr
Boiler sizes
1–50 L
Vacuum
100–0.01 Torr

Designed and built in the USA · GMP documentation available (IQ, OQ, PQ, FAT, SAT)

Overview

Built for cannabinoid fractions

Crude extract is a mixture of cannabinoids, terpenes, waxes, and residual solvent whose boiling points sit close together under vacuum. Separating them cleanly takes theoretical plates, not just heat. The 9200 runs a rotating Teflon band inside the column, which keeps a thin, continuously renewed film against the wall and delivers a high plate count in a short column with very low hold-up.

The practical result is fewer passes. Where multi-pass setups recycle heads and tails to chase potency, a single controlled run typically lands 90–95% total active cannabinoids — less thermal history on the product and less rework on the floor.

  • 90–95% total active cannabinoids on the first pass
  • No recycling of heads and tails through repeat distillations
  • Run parameters saved, recorded, and reviewable
  • Remote viewing from off the production floor
  • IQ, OQ, PQ, FAT, and SAT packages available

Separation

  • Spinning band column, 21 mm or 32 mm
  • Condenser and condenser bath
  • 3-stage stainless cold trap
  • Vacuum operation to 0.01 Torr

Handling

  • Boiler sized to your batch, 1–50 L
  • Automatic fraction collector
  • Teflon band to 225 °C
  • Charge prep guidance for your crude

Control

  • PC and automatic controller
  • Saved and recorded run parameters
  • Remote viewing of a live run
  • GMP documentation packages
Condenser and column sit above the boiler, vacuum and cold trap on one side, fraction collector and controller on the other. See the annotated system diagram for how the subsystems connect.
ConfigurationBoiler sizesThroughputTypical use
Small scale5, 12 L0.5–1.5 L/hrR&D, method development, small commercial batches
Mid scale12, 22 L1–2 L/hrSteady daily production on a single shift
Production scale22, 50 L2–3.5 L/hrHigh-volume refining where uptime drives the schedule
ControlAutomatic control with PC software
BandTeflon band
Boiler sizes1–50 L
Columns21 mm and 32 mm
Column length30 cm
Vacuum range100–0.01 Torr
Cold trap3-stage stainless steel
Fraction collectorAutomatic, by vapour temperature
Typical purity90–95% total active cannabinoids
DocumentationIQ, OQ, PQ, FAT, SAT
Charge preparation matters. The system runs best on winterized, solvent-stripped, decarbed crude. Feeding untreated extract shortens run time between cleanings and darkens the distillate.

Ready to refine cleaner distillate?

Talk with a B/R applications specialist about spinning band systems and process fit for your crude.

Request a quote